Congratulation Siwen An ‑ New doctor in electronics

Tue 21 Jun 2022 12:49

Friday June 17, it was time for Siwen An to present her doctoral thesis "Spectroscopic and Microscopic X-ray Fluorescence Analysis for Environmental and Industrial Applications" which she did with a successful result.

Four persons standing next to eachother smiling toward the camera
Siwen An with her supervisors. From the left: Associate Prof. Göran Thungström, Associate Börje Norlin and Dr. David Krapohl.

Siwen started with presenting her thesis. After that it was time for opponent Professor Yuying Huang, Shanghai Institute of Applied Physics, to ask his questions. After the opponent it was the grading committees turn to ask their questions. In the grading committe participated Professor Richard Brenner, Uppsala University, Professor Anders Hallén, KTH Royal Institute of Technology and Dr. Gabriella Josefsson, Hamamatsu Photonics.

Supervisor to Siwen An was Associate Prof. Börje Norlin and co-supervisor where Associate Prof. Göran Thungström and Dr. David Krapohl, Mid Sweden Univeristy.

Abstract

Heavy metals are well-known environmental pollutants due to its potential impact on associated ecosystems and human health. Thus, it is important to monitor the levels of heavy metals in the environment. X-ray fluorescence (XRF) analysis is a powerful and effective screening tool in measuring the concentration of multi-elements simultaneously.

This thesis provides insight into development and implementation of XRF instruments for environmental monitoring and industrial process control. The XRF method was compared with a commercial scanning electron microscope with energy dispersive spectroscopy (SEM-EDS) for fly ash samples. Qualitative analysis and semi-quantitative analysis of Na, S, Cl, K and Cd in incineration fly ash were performed with these two similar techniques. One of the challenges of using XRF is the scattering background noise from the primary beam, which decreases the detection limit and the sensitivity of the measurement system. Hence, an X-ray beam filter was chosen to suppress the background noise for a specific element, Cr, in leachate. Numerical simulations and experiments were developed to find the proper filter material and thickness by calculating the X-ray fluorescence intensities and the signal-to-noise ratio. The developed system is capable of online monitoring of Cr levels, to certify that the concentration is below the threshold level in leachate. An XRF prototype was built and calibrated for underwater Hg analysis in maritime wet sediment using a radioisotope source. The presented results show that it is possible to detect Hg by K-shell emission thus enabling XRF analysis for sediment underwater.

For non-homogeneous samples, an image revealing the elemental distribution can be achieved by micro-XRF (µ-XRF). XRF mapping of element distributions on a microscopic level was obtained by using scanning XRF microscopy and full-field XRF projection microscopy (FF-XRF). The spatial resolution of the scanning XRF imaging setup using an X-ray tube is in the order of 100 µm, but need to be further improved to measure the homogeneity of S on individual fiber level in pulp and paper industry. For the scanning technique, it is a tradeoff between resolution and measurement time. Another technique is FF-XRF imaging, and a setup was implemented using an energy resolving pixel detector and X-ray optics. The capabilities and limitations of using X-ray optics in XRF imaging systems have been identified. These microscopy measurements can guide further comprehensive environmental and industrial monitoring missions, utilizing elemental distribution information.

Link to thesis in Diva

av

av

av

av

av

av

av

av

av

av

av

av

av

av

av

av

Logo

Recommended

The page was updated 6/21/2022