Claes Mattsson

Spara favorit

Forskningsområden

Radiations detectors, Infrared detectors, Fabrication of membrane based thermal detectors.

Pågående forskning

Current research focuses on infrared radiations absorber structures and low cost IR detector systems for detection of methane gas.

Undervisning

Teaching in the subject areas of Microprocessor systems, Digital electronics(including PLC), Semiconductor devices and processing.

Publikationer

Artiklar i tidskrifter

Ashraf, S. , Mattsson, C. , Fondell, M. , Lindblad, A. & Thungström, G. (2015). Surface modification of SU-8 for metal/SU-8 adhesion using RF plasma treatment for application in thermopile detectors. Materials Research Express, vol. 2: 8  

Ashraf, S. , Mattsson, C. , Thungström, G. & Rödjegard, H. (2014). Integration of an interferometric IR absorber into an epoxy membrane based CO2 detector. Journal of Instrumentation, vol. 9: 5, ss. Art. no. C05035  

Mattsson, C. , Thungström, G. , Rödjegård, H. , Nilsson, H. & Martin, H. (2009). Experimental evaluation of a thermopile detector with SU-8 membrane, in a carbon dioxide meter setup. IEEE Sensors Journal, vol. 9: 12, ss. 1633-1638.  

Mattsson, C. , Thungström, G. , Bertilsson, K. , Nilsson, H. & Martin, H. (2009). Fabrication and characterization of a design optimized SU-8 thermopile with enhanced sensitivity. Measurement science and technology, vol. 20: 11, ss. 115202  

Lars, H. , Björk, M. , Cederquist, B. , Mattsson, C. , Thungström, G. & Fröjdh, C. (2009). Point Dose Profile Measurments using Solid State Detectors in Characterization of Computed Tomograhy Systems. Nuclear Instruments and Methods in Physics Research Section A, vol. 607: 1, ss. 223-225.  

Mattsson, C. , Bertilsson, K. , Thungström, G. , Nilsson, H. & Martin, H. (2009). Thermal simulation and design optimization of a thermopile infrared detector with SU-8 membrane. Journal of Micromechanics and Microengineering, vol. 19: 5, ss. 055016  

Mattsson, C. , Thungström, G. , Bertilsson, K. , Nilsson, H. & Martin, H. (2008). Design of a Micromachined Thermopile Infrared Sensor with a Self-Supported SiO2/SU-8 Membrane. IEEE Sensors Journal, vol. 8: 12, ss. 2044-2052.  

Thungström, G. , Mattsson, C. & Rönnqvist, C. (2007). Fabrication and Characterization of Silicon Detectors for use in Radiotherapy Dosimetry, Pre-irradiated by High Energy Electrons. Nuclear Instruments and Methods in Physics Research Section A, vol. 576: 1, ss. 209-214.  

Andersson, H. , Mattsson, C. , Thungström, G. , Lundgren, A. & Nilsson, H. (2006). The effect of mechanical stress on lateral-effect position sensitive detector characteristics. Nuclear Instruments and Methods in Physics Research Section A, vol. 563: 1, ss. 150-154.  

Nilsson, H. , Mattsson, C. , Norlin, B. , Fröjdh, C. , Bethke, K. & De Vries, R. (2005). Evaluation of the charge sharing effects on spot intensity in XRD setup using photon counting pixel detectors. Nuclear Instruments and Methods in Physics Research Section A, vol. 563: 1, ss. 182-186.  

Mattsson, C. , Bertilsson, K. , Thungström, G. & Nilsson, H. (2004). Manufacturing and characterization of a modified four-quadrant position sensitive detector for out-door applications. Nuclear Instruments and Methods in Physics Research Section A, vol. 531: 1-2, ss. 134-139.  

Doktorsavhandlingar, sammanläggningar

Mattsson, C. (2009). Design, Fabrication and Optimization of Thermal Radiation Detectors Based on Thin Polymer Membranes. Diss. (Sammanläggning) Sundsvall : Kopieringen Mittuniversitetet, 2009 (Mid Sweden University doctoral thesis : 73)  

Konferensbidrag

Ashraf, S. , Mattsson, C. , Thungström, G. , Gaynullin, B. & Rödjegård, H. (2018). Evaluation of a CO2 sensitive thermopile with an integrated multilayered infrared absorber by using a long path length NDIR platform. I I2MTC 2018 - 2018 IEEE International Instrumentation and Measurement Technology Conference : Discovering New Horizons in Instrumentation and Measurement, Proceedings.. S. 1--6.  

Gaynullin, B. , Bryzgalov, M. , Hummelgård, C. , Mattsson, C. , Rödjegård, H. & Thungström, G. (2017). Pressure characterization and resolution limits' investigation of high accuracy NDIR Methane sensor for environmental applications. Paper presented at the 14th International Workshop on Advanced Infrared Technology and Applications, AITA 2017, Québec City, Canada, September 27-29, 2017

Ashraf, S. , Mattsson, C. & Thungström, G. (2016). Fabrication of a mid-Ir sensitive thermopile detector. I Proceedings of IEEE Sensors. (IEEE Sensors)  

Gaynullin, B. , Hummelgård, C. , Mattsson, C. , Rödjegård, H. & Thungström, G. (2015). Comparative study of CO2 and CH4 pressure dependence in the HPP NDIR platform. Paper presented at the 2015th FPIRC International Summer Conference

Ashraf, S. , Mattsson, C. , Thungström, G. & Rödjegard, H. (2014). Design of a multilayered absorber structure based on SU-8 epoxy for broad and efficient absorption inMid-IR sensitive thermal detectors. I Proceedings.. S. 938--941.  

Mattsson, C. , Thungström, G. , Bertilsson, K. , Nilsson, H. & Martin, H. (2008). Fabrication and evaluation of a thermal sensor formed on a thin photosensitive epoxy membrane with low thermal conductivity. I PROCEEDINGS OF THE 17TH INTERNATIONAL VACUUM CONGRESS/13TH INTERNATIONAL CONFERENCE ON SURFACE SCIENCE/INTERNATIONAL CONFERENCE ON NANOSCIENCE AND TECHNOLOGY. (Journal of Physics: Conference Series (Online Edition)). S. 082048-  

Mattsson, C. , Thungström, G. , Bertilsson, K. , Nilsson, H. & Martin, H. (2007). Development of an infrared thermopile detector with a thin self-supporting SU-8 membrane. I Proceedings of IEEE Sensors. New York : (IEEE Sensors). S. 836--839.  

Licentiatavhandlingar, sammanläggningar

Mattsson, C. (2007). Fabrication and Characterization of Photon Radiation Detectors. Lic.-avh. (Sammanläggning) Institutionen för informationsteknologi och medier, 2007 (Mid Sweden University licentiate thesis : 29)